J Adv Periodontol Implant Dent. 16(1):1-3. doi: 10.34172/japid.2024.011

Letter to the Editor

Effect of auto-adaptive metal artifact reduction (aMAR) program in cone-beam computed tomography on assessing pre-implant bone levels

Farida Abesi * ORCID logo

Author information:
Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran

*Corresponding author: Farida Abesi, Email: faridaabesi@yahoo.fr

Abstract

This research aimed to introduce an auto-adaptive metal artifact reduction (aMAR) algorithm in cone-beam computed tomography (CBCT) to assess the levels of the pre-implant alveolar crest. Dental implants as a treatment modality for edentulous patients consist of a titanium alloy, which creates a metal artifact, resulting in a dark dental structure in the CBCT scans. Metallic artifacts are limiting factors for the precise detection in CBCT images. These are related to the dark areas around materials and metallic structures (e.g., restorations, implants, and endodontic instruments). To overcome this problem, the metal artifact reduction (MAR) program has been recommended as a post-procedure stage for CBCT image reconstruction. Recent developments offer CBCT scanners with an aMAR option with a greater dynamic range to help overcome the challenges of peri-implant bone evaluation to reach accurate dental diagnoses.

Keywords: CBCT, Implant, Metal artifact reduction

Copyright and License Information

© 2024 The Author(s).
This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Dear Editor;

Dental implants, as a treatment option for edentulous patients, are made of a titanium alloy that creates a metal artifact and makes the dental structures appear significantly darker in CBCT images. CBCT is one of the essential imaging techniques in implant treatment planning and placement.1 Cross-sectional images by CBCT provide many advantages, from evaluating the implant site for alveolar crest levels and proximity to critical anatomic structures, including the inferior alveolar nerve and maxillary sinus floor. Therefore, based on these data, the clinicians can plan the surgical procedure accurately to place the implant in the appropriate location.2

Beam-hardening and streak artifacts are limiting factors for the precise detection in CBCT images. These are related to the dark areas around materials and metallic structures (e.g., restorations, implants, and endodontic instruments).3,4 The metallic artifact can arise from a combination of many phenomena, such as limitations in the physical process and photon starvation. Metallic objects absorb photons, impeding their detection by the sensor, thereby resulting in artifacts that can compromise the clinical interpretation of CBCT images and data close to the metallic structure. This can lead to poor-quality or non-diagnostic scans and reduced reliability in interobserver and intraobserver assessments.5 A notable challenge posed by the lack of data close to the implant fixture is the inability of clinicians to precisely evaluate pre-implant bone levels and the overall health near the bone using CBCT scans.6

To address this problem, the metal artifact reduction (MAR) program has been implemented as a post-procedure stage for CBCT image reconstruction. The MAR tool aims to mitigate artifacts and improve the quality of CBCT images. This algorithm is integrated into the tomographic image reconstruction system to reduce or remove image artifacts. Several companies offer commercial access to these tools for various CBCT equipment, including Newtom (Verona, Italy), Planmeca (Helsinki, Finland), Soredex (Tuusula, Finland), and Vatech (Hwaseong, Korea).7

Various approaches for MAR on CBCT imaging have been examined in previous research. One study involving patients with metallic devices in their bodies demonstrated that applying a pre-processing MAR program can produce superior image quality.8 Another study increased the mAs factor or peak tube potential levels, resulting in improved image quality as higher beam energy was not fully absorbed by metallic structures.9 Additionally, numerous post-processing techniques for MAR have been investigated, including the multiplanar reconstruction algorithm, which reduced artifacts and enhanced the diagnostic quality of scans.10 In the mentioned studies, the rate of metal artifacts was evaluated through visual assessment.

However, several studies have indicated that the efficiency of the MAR tool may be limited when addressing periodontal and peri-implant defects. Additionally, in some cases, the MAR tool may even lead to a decrease in diagnostic accuracy for detecting root fractures.7,11 One limitation of the MAR tool is that it equally removes both the metal artifacts and dental anatomical structures in CBCT images. In recent years, some advancements have been made in post-processing programs to reduce metallic artifacts. For example, recent developments offer CBCT scanners with an auto-adaptive MAR (aMAR) option, which has a greater dynamic range and superior technical specifications that can help overcome the challenges of peri-implant bone evaluation to have accurate dental diagnostics.However, research on applying the aMAR algorithm in CBCT scans remains limited, particularly in cases involving dental implants.12

Moreover, many other approaches have been tested to minimize metal artifacts in CBCT scans and increase detection accuracy in different dental problems.3 In this regard, some researchers have proposed that reducing metal artifacts within the field of view, which can increase the overall quality of the images while providing higher spatial resolution,13 as well as the CBCT unit and imaging parameters, could influence the formation of artifacts.14 On the other hand, several studies have examined the metallic artifacts generated by different dental implant materials, such as ceramic, titanium, and zirconia, in CBCT images.1,15,16 For instance, research by Demirturk Kocasarac et al15 indicated that implants containing titanium, whether pure titanium or a titanium-zirconia combination, exhibited fewer artifacts compared to zirconia implants. Similarly, Sancho-Puchades et al17 found that ZrO2 implants resulted in a threefold increase in metallic artifacts compared to titanium implants. However, despite these efforts, none of these methods could eliminate the noise induced by metallic objects in CBCT scans. Therefore, it is imperative to explore factors that could contribute to improved image quality by minimizing image artifacts.

In contemporary radiology, there is a growing emphasis on obtaining accurate data quickly and automatically. The accessibility of source codes and datasets in deep learning has attracted significant attention. Consequently, numerous studies have evaluated the diagnostic efficacy of integrating artificial intelligence with CBCT imaging for identifying oral and maxillofacial anatomical landmarks and lesions. Researchers have reported differing degrees of accuracy in these assessments.14 On the other hand, there is limited research on evaluating different clinical reconstruction algorithms and networks in the aMAR program and CBCT imaging technique. Moreover, there are some gaps in our knowledge about assessing the clinical applications and diagnostic performance of aMAR in dental and maxillofacial radiology, describing the value, impact, and reliability of aMAR in CBCT scans, especially in the case of multiple implants, which would benefit from further research.


Competing Interests

None declared.


Ethical Approval

Not applicable.


Funding

Not applicable.


References

  1. Warren EK, Vaddi A, Tadinada A. A comparative evaluation of the metallic artifact generated by a ceramic dental implant and a titanium dental implant imaged on cone-beam computed tomographic scans: an ex vivo study. JADA Found Sci 2022; 1:100007. doi: 10.1016/j.jfscie.2022.100007 [Crossref] [ Google Scholar]
  2. Benavides E, Rios HF, Ganz SD, An CH, Resnik R, Reardon GT. Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent 2012; 21(2):78-86. doi: 10.1097/ID.0b013e31824885b5 [Crossref] [ Google Scholar]
  3. Bechara BB, Moore WS, McMahan CA, Noujeim M. Metal artefact reduction with cone beam CT: an in vitro study. Dentomaxillofac Radiol 2012; 41(3):248-53. doi: 10.1259/dmfr/80899839 [Crossref] [ Google Scholar]
  4. Talachi F, Abesi F, Ezoji F, Mahjoub S, Ghorbani H, Bijani A. Comparison of accuracy cone-beam computed tomography and digital bitewing radiography for detection of recurrent caries under various restorative materials: in vitro study. Oral Radiol 2023; 39(4):722-30. doi: 10.1007/s11282-023-00690-x [Crossref] [ Google Scholar]
  5. Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U. Artefacts in CBCT: a review. Dentomaxillofac Radiol 2011; 40(5):265-73. doi: 10.1259/dmfr/30642039 [Crossref] [ Google Scholar]
  6. Mohammadpour Z, Foroughi R, Abesi F, Bijani A, Haghanifar S. Radiographic comparison of the relation between mandibular third molar root and inferior alveolar canal in panoramic radiography and cone-beam computed tomography. J Babol Univ Med Sci 2021; 23(1):289-96. doi: 10.22088/jbums.23.1.289.[Persian] [Crossref] [ Google Scholar]
  7. Queiroz PM, Santaella GM, Groppo FC, Freitas DQ. Metal artifact production and reduction in CBCT with different numbers of basis images. Imaging Sci Dent 2018; 48(1):41-4. doi: 10.5624/isd.2018.48.1.41 [Crossref] [ Google Scholar]
  8. Mahnken AH, Raupach R, Wildberger JE, Jung B, Heussen N, Flohr TG. A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Invest Radiol 2003; 38(12):769-75. doi: 10.1097/01.rli.0000086495.96457.54 [Crossref] [ Google Scholar]
  9. Vande Berg B, Malghem J, Maldague B, Lecouvet F. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol 2006; 60(3):470-9. doi: 10.1016/j.ejrad.2006.08.008 [Crossref] [ Google Scholar]
  10. Robertson DD, Weiss PJ, Fishman EK, Magid D, Walker PS. Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. J Comput Assist Tomogr 1988; 12(2):236-41. doi: 10.1097/00004728-198803000-00012 [Crossref] [ Google Scholar]
  11. Kamburoglu K, Kolsuz E, Murat S, Eren H, Yüksel S, Paksoy CS. Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode. Dentomaxillofac Radiol 2013; 42(8):20130176. doi: 10.1259/dmfr.20130176 [Crossref] [ Google Scholar]
  12. Abesi F, Jamali AS, Zamani M. Accuracy of artificial intelligence in the detection and segmentation of oral and maxillofacial structures using cone-beam computed tomography images: a systematic review and meta-analysis. Pol J Radiol 2023; 88:e256-63. doi: 10.5114/pjr.2023.127624 [Crossref] [ Google Scholar]
  13. Nikpour A, Abesi F, Khafri S. Quantitative and the quality of the maxillary sinus in cone-beam computed tomography (CBCT) images in a population of northern Iran. J Mashhad Dent Sch 2024; 48(1):589-95. doi: 10.22038/jmds.2023.23620.[Persian] [Crossref] [ Google Scholar]
  14. Vasconcelos KF, Nicolielo LF, Nascimento MC, Haiter-Neto F, Bóscolo FN, Van Dessel J. Artefact expression associated with several cone-beam computed tomographic machines when imaging root filled teeth. Int Endod J 2015; 48(10):994-1000. doi: 10.1111/iej.12395 [Crossref] [ Google Scholar]
  15. Demirturk Kocasarac H, Ustaoglu G, Bayrak S, Katkar R, Geha H, Deahl ST 2nd. Evaluation of artifacts generated by titanium, zirconium, and titanium-zirconium alloy dental implants on MRI, CT, and CBCT images: a phantom study. Oral Surg Oral Med Oral Pathol Oral Radiol 2019; 127(6):535-44. doi: 10.1016/j.oooo.2019.01.074 [Crossref] [ Google Scholar]
  16. Vasconcelos TV, Bechara BB, McMahan CA, Freitas DQ, Noujeim M. Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol 2017; 123(2):265-72. doi: 10.1016/j.oooo.2016.10.021 [Crossref] [ Google Scholar]
  17. Sancho-Puchades M, Hämmerle CH, Benic GI. In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography. Clin Oral Implants Res 2015; 26(10):1222-8. doi: 10.1111/clr.12438 [Crossref] [ Google Scholar]
Submitted: 30 Apr 2024
Accepted: 18 May 2024
First published online: 28 May 2024
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - FireFox Plugin)

Abstract View: 506
PDF Download: 416
Full Text View: 2