Logo-japid
J Adv Periodontol Implant Dent. 10(2):77-84. doi: 10.15171/japid.2018.012

Research Article

Patterns of stress and strain in complete-arch prostheses supported by four or six implants: A literature review of finite element analyses

Nasrin Keshavarz Valian 1, Mohammad Reza Talebi Ardakani 1, Alireza Aziz Ahari 2, Mohammad Taghi Baghani 3, Shireen Shidfar 4, *
1Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2Department of Radiology, Rasool-e-Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
3Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
4Department of Periodontics, School of Dentistry, Qom University of Medical Sciences, Qom
*Corresponding Author ; E-mail: shireen@yahoo.com

Abstract

Background

Tilted implants have been recommended as an alternative to the bone graft procedures in implant sites although with possibly higher stress concentrations. This study reviews finite element studies to evaluate patterns of stress and strain in complete-arch prostheses supported by 4‒6 implants.

Methods

A literature search was performed using the online databases. Articles published in English from 2003 to 2015 were reviewed. A total of 100 articles were found related to the subject and after evaluating the titles and abstracts, 18 studies were selected.

Results

By increasing the number of implants, a reduction was detected in the amount of stress in the bone and implants, while in others, the stress level did not change with the increase in the number of implants.

Conclusion

According to finite element analyses, placing a distal implant in an angular position results in better distribution of forces and stresses. Using less cantilever lengths would reduce the stress.

Keywords: All-on-four implant treatment design, all-on-six implant treatment design, finite element analysis, stress

Copyright

© 2018 The Author(s).
This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Introduction

Edentulism is a common condition in elderly patients due to bad oral hygiene, caries and periodontal diseases. 1 Clinicians are faced with increasing need for a solution for these patients, which is due to increased expectations and lifestyle changes. 2 These individuals usually have significant bone loss in the alveolar ridge, which might be caused by physiologic or pathologic reasons. 3,4 A routine treatment for edentulism is the use of conventional dentures while clinical studies comparing patients using dentures with those using implants showed just a slight improvement in quality of life. 5 These problems and factors such as the predictable results of implant-based prosthetic treatments, awareness of the society and many other factors lead to the increased demands for implants. 6 Although designing and presenting these treatments require careful attention, cases such as choosing the right area for implant placement, an exact design of the prosthesis, implants’ attachment to each other, their proper diameter and length, the material quality and the prosthesis type in these treatments should be attended carefully to achieve the desired results. In edentulous patients, limitations in the anatomy of the residual bone (such as mandibular canal and maxillary sinus) cause problems in dental implant placement. 7,8 There are various materials and techniques to overcome this problem. 9,10 Among these methods, advanced augmentation procedures to achieve adequate bone support for placing standard implants (length: 10‒12 mm and diameter: 3.5 mm) in an extremely atrophic posterior jaw should be mentioned. 11 However, all of these methods result in the risk of morbidity and complications in patients (such as infection and loss of the graft materials), costs and increased treatment time. 12

To avoid extensive bone graft procedures and to optimize utilization of the patient's own bone, use of tilted or short implants are alternative methods. 13-19

Maló et al 23 introduced (All-on-Four) method. According to this method, four implants will be sufficient for complete restoration of the jaw. Two implants are placed in the anterior areas of jaws and the two others are placed anterior to the mental foramen. Anterior implants are inserted parallel and posterior implants with an approximately 30º distally so that the length of the cantilever is shortened for further prosthetic rehabilitation. By tilting the posterior implant distally, the most posterior placement of the implant is obtained. This permits engagement of implants in the sinus wall and nasal fossa in the maxilla. 20-23 Nonetheless, according to biomechanical and in vitro studies, tilted implants lead to an increase in the peri-implant bone stress due to bending. 24,25 These studies were conducted on single implants placed linearly. In contrast, in multiple implants, the rigidity of the prostheses can reduce implant bending. Earlier evaluations have shown that when the posterior implants are placed in a tilted manner, no further loss of bone is detected compared to the parallel ones. 26

Using four implants for full reconstruction of the maxilla is supported by clinical studies, 27,28 but it is suggested that use of more implants (about 6) can be safer. 29-31

Among important biomechanical factors of the implant success, there is stress or the way of force distribution per unit area and strain or amount of change in length per original length when subjected to the applied force. These additional stresses cause extra load and possible failure of implant in future. Stress-related factors can cause complications in short or long term, including implant fracture, crestal bone loss, porcelain fracture, loss of retention, implant component fracture and screw loosening. Therefore, stress distribution is the most important factor, which should be evaluated before the treatment. 32

In 1976, Weinstein used FEA for the first time in dental implants. 33 Finite element analysis (FEA) has been extensively utilized in various studies and has been successfully utilized in engineering and biomaterial fields since 1990. FEA includes numerous processes for evaluating structures. Typically, a given topic is much more complicated than can be solved by the usual analysis method. This problem can be stress analysis, heat transfer and large deformations. FEA is based on dividing the problem into smaller and simpler units to find a solution for it. 34

In the field of implant dentistry, FEA permits calculation of stress distribution in the contact area of the implants with the adjacent bone. However, some assumptions have a major impact on the predictive accuracy of the FEA model. These include model geometry, material properties, applied boundary conditions, and the bone–implant interface. To eliminate these, advanced digital imaging techniques can be utilized. 35

This study aims at reviewing finite element analysis to assess patterns of stress and strain in complete-arch prostheses supported by 4‒6 implants.


Methods

An electronic literature search was run using the online databases EMBASE, PubMed and Google Scholar. The following keywords were used to search (in the title and/or in the abstract):

1) "Finite Element" AND "All-on-Four"

2) "Finite Element" AND "All is Four"

3) "Finite Element" AND "All-on-4"

4) "Finite Element" AND "All is 4"

5) "Finite Element" AND "Tilted AND Implant"

6) "Finite Element" AND (Tilted AND Implant)

7) "Finite Element" AND (Tilting AND Implant)

8) "Finite Element" AND (Inclined AND Implant)

9) "Finite Element" AND (Angulated AND Implant)

10) "All is 6" OR "All is Six

Articles in the English language were included. The search included studies involving human subjects and in vitro investigations. No restrictions were employed regarding the design of studies. Additional search was performed through the references of all relevant articles.

The following inclusion criteria were applied: (1) root-form implants were used; (2) some implants were placed in tilted fashion; (3) 4‒6 implants were placed in each jaw; and (4) stress and strain were calculated in peri-implant bone.

When it was necessary, the full texts of the articles were reviewed.


Results

Articles published in English from 2003 to 2015 were reviewed. A total of 100 articles were found on the subject and after evaluating the titles and abstracts, 18 studies, which were conducted using "Finite Element Analysis" were finally selected. These 18 studies are summarized in Table 1-5 and categorized according to the type of study, date of publication, type of jaw, objectives and the study results.

The articles were examined according to the effects of the number of implants, different angles of implants, cantilever length and stress levels on cortical and trabecular bone.

Table 1. Studies included in the review
Author Study type Date of publication Studied type of jaw Objectives Results
Watanabe 25 Finite element analysis (FEA)2003MandibleEvaluation of the stress distribution produced by different degrees of implant body inclination and various positions and loading directions.
Compressive stress levels are higher in the inclined implants. The compressive stress was higher on the cortical bone adjacent to direction of inclination, and tensile stress was pronounced in the opposite direction.
Lan 39 FEA2008MandibleEvaluation of produced bony stress by different implant tilting during normal masticatory loadNot all types of implant body tilting cause stress concentration.
Bevilacqua 40 FEA2008MandibleEvaluation of Stress rate around tilted implants against vertical implantsDistal tilted implants in fixed prostheses without cantilever reduce the stress of bone around the implants.
Sasaki 41 FEA2008MandibleAssessing mechanical risk factors of All-on-Four by evaluating stress distribution on implants and their surrounding bone.Stress concentration was detected around distal of the tilted posterior implants in the left of jaw. In cases of more spongy bone with less elastic properties, the stress concentration was higher.
Table 2. Studies included in the review
Author Study Type Date of publication Studied type of jaw Objectives Results
Bellini 42 FEA2009MandibleEvaluation of stress-induced patterns in cortical bone of mandible with three implant-supported prosthetic designs
There were no significant differences in patterns of stress between tilted implant designs with 5- and 15-mm cantilever. The tilted design of the 15 mm cantilever produced more stress than the 5 mm cantilever.
Bellini 43 FEA2009MaxillaEvaluation of stress patterns in the implant-bone interface in tilted implant designs and not tilted ones in maxillaTilted designs showed a lower amount of compressive stress compared to not tilted ones.
Cruz 44 FEA2009MandibleEvaluation and comparison of stress distribution around two prosthetic implant systemsAngular systems did not concentrate the stress at any point of the implant. The stress distribution in both systems was very similar to each other.
Silva 36 FEA2010MaxillaComparison of the biomechanical behaviour of All-on-Four system with prosthesis supported by implants in Maxilla with tilted dental implants. Situation patterns and stress distribution were comparable between the two different models. Increasing number of implants reduces the highest stress levels of Von Mises and cantilever increases the stress significantly.
Table 3. Studies included in the review
Author Study type Date of publication Studied type of jaw Objectives Results
Bevilacqua 45 FEA2010PremaxillaComparison and evaluation of the stress transferred to tilted implants against vertical implants and adjacent bone in maxillaDistal tilted implants, that are hardly splinted by dentures, reduce the stress in the peri-implant bone.
Takahashi 38 FEA2010MandibleEvaluation of the differences in the stress in the peri-implant cortical bone in models with 6 and 8 implants.Using 4 implants or inclined implants increases the stress in the peri-implant cortical bone. However, in simultaneous use of short cantilevers, tilting the implants reduce stress in the peri-implant cortical bone.
Naini 46 FEA2011Mandible Evaluation and comparison of concentration of stress in the peri-implant bone in two designs. 1) design with 4 implants with distal implants of 45 °, 2) 4 parallel implants and vertical to the occlusal plane) and two loading conditions.
None of the designs showed better performance than any of the loading states.
Posterior tilted implants were under stress in all situations.
Table 4. Studies included in the review
Author Study type Date of publication Studied type of jaw Objectives Results
Fazi 37 FEA2011MandibleAnalysis of Stress Distribution in Bone, Implant and Prosthesis in Different Implant Designs in Mandible ImplantationIn the designs with parallel implants, 4 and 5 implants cause same stress distribution. Using 4 implants with distal tilted implants of 34-degree caused stress reduction in the bone and implants.
Malhotra 47 FEA2012Mandible
The evaluation of the effect of tilting distal implants at different angles (30 ° and 40°) with different lengths of cantilever (4mm and 12 mm) on the distribution of stress and strain in All-on-Four.
Increasing the angle of the tilted distal implants does not significantly increase the stress level. In addition, the mandible’s structure plays an important role during the treatment planning for complete edentulous patients.
Ozdemir 48 FEA2012MandibleEvaluation of the force effect on implant and bridges in All-on-Four and alternate designs In the presence of vertically atrophied mandible although (All-on-Four) method is a clinically possible method, short implants reduce the amount of transferred stress to the supportive bone. The concentration of stress in the cortical bone was greater than the spongy bone. The highest amount of stress in the peri-implant cortical bone was located at distal. By reducing the number of implants, no reduction the plan success rate was observed.
Table 5. Studies included in the review
Author Study type Date of publication Studied type of jaw Objectives Results
Baggi 49 FEA2013Maxilla-MandibleComparing two different repair methods for complete jaw reconstruction by placement of 4 implantsThe distal tilted implants presented a better load transfer compared to vertical implants, although the calculated stress in both conditions was physiologically acceptable.
Hussein 50 FEA2013MandibleAnalysis of the Effects of Different Positions of Anterior Implants in Design (All-on-Four).More concentration of stress was detected on the loading side nearby the posterior implants. The change in the position of anterior implants in the design (All-on-Four) effects the distribution of strain and stress in all of the designs.
Sannino 51 FEA2013MaxillaStudying the Biomechanical Behaviour of Supported Prostheses by All-On-Four Method by Comparing Three Degree Tilts in Distal Implants.Maximum level of stress was permanently detected in the distal implant necks. Amount of stress in distal implants was enlarged in apical direction with tilting.
Seker 52 FEA2014Maxilla Functional stress analysis around the implants and surrounding tissues in posterior maxillary with grafted and non-grafted sites considering the acceptability of various therapeutic options.
The ability to absorb stress is not adequate and is much less than other supporting tissues. Fixed partial prosthesis using short and wide implants with bicortical stability is the most reasonable method for posterior maxillary area.

A. Number of implants

Silva et al 36 showed that stress location and distribution in both models with 4 and 6 implants are similar and increasing the number of implants decreases the highest Von Mises stress. Also in a study by Fazi et al 37 FEA was used to evaluate various implant designs of mandibular fixed prostheses. In this study in which the number of implants varied from 3 to 5, it was shown that implants with parallel position in all the designs exhibited similar stress distribution.

Takahashi et al 38 examined the effect of implant number on distribution of stress in cortical bone of the mandible in the All-on-Four method. The results showed that by placing 4 implants, stress in the cortical bone around the implants increases compared to 6 implants.

B.Implant angles

In a study by Lan et al, 39 the provided stress due to different angles of implant placement was studied. Implants were placed with angles of zero or 15 degrees facing the mesial and distal aspects. This study showed that under horizontal and vertical forces, the highest compressive stresses were located in the cortical bone around the ​implant neck and the results suggested that not all of the tilted implants restored with splinted crowns displayed concentration of stress.


Discussion

All-on-Four method was first introduced by Malo et al. 20 As mentioned, based on this concept, 4 implants will be sufficient for complete jaw reconstruction. From these 4 implants, 2 will be placed in the anterior of the alveolus and 2 will be inserted in the anterior area of the mental foramen with a 30° angle toward the distal aspect.

In a clinical study by Malo et al, 23 complete reconstruction of a jaws supported by 4 implants was evaluated. This retrospective study included 165 complete reconstructions that were immediately loaded and were assessed for 5 years. Fifty-five patients were in the double jaw reconstruction group and 55 patients were in the single jaw reconstruction group. The primary results included cumulative survival of prosthesis and implant and the secondary findings included marginal bone level after 5 years and biological and mechanical complications.

According to the results, one-arch or double-arch restoration in edentulous patients did not display a significant difference in terms of the survival rate.

Malo et al 20 evaluated the method of All-on-Four for complete reconstruction of edentulous mandible in another clinical study. The results were evaluated clinically for 7 years and radiographically for 5 years. Prosthetic survival rate was 99.7% and the implant’s cumulative survival rate was 95.4%. Therefore, the high survival rate of the prosthesis and implant and the high marginal bone level confirmed the safety of the treatment plan (All-on-Four).

According to the article series presented in Table 1 and the above-mentioned clinical studies, it seems that All-on-Four method is a safe modality of complete reconstruction of the jaw.

Takahashi et al 38 declared that using angular implants increased stress in the peri-implant cortical bone. However, using these implants in association with a short cantilever reduced stress in the peri-implant cortical bone. Baggi et al 49 examined two models of full-jaw restoration using 4 implants. In the first technique, two implants were placed vertically at mesial aspect and two posterior implants were inserted with a tilt of 30°, and in the second model every 4 implants were placed with no tilt and in platform-switch fashion. The results of this study confirmed that prostheses which were supported by tilted distal implants showed a more efficient and monotonous load distribution than the vertical position of all the implants. Moreover, distal tilted implants reduced the stress between the bone and the implant in the distal region, but they could cause high tensile stress in the distal crest depending on the bone shape and the force type.

In another study, Bevilacqua et al 40 compared the stress transmitted to the bone around the implant in the maxilla in tilted and vertical implants. In the developed models, the distal implants were located at angles of 0, 15, 30 and 45 degrees. According to the results, the highest level of stress in the peri-implant bone was recorded for vertical implants (75 MPa) (for implants at the distal aspect) and the lowest for implants at the mesial aspect (35 MPa). Distal tilted implants that had been hardly splint together by fixed denture reduced the stress in the peri-implant bone.

Sannino et al 51 used FEA to evaluate the All-on-Four Model, using three different degrees (15°, 30° and 45°) in the distal implants. According to the results, there were no significant differences between the 15° and 30° models in terms of Von Mises stress values and the 45° model was the riskiest model in terms of stress in the bone surrounding the implant. The maximum stress was mostly focused in the neck area of the distal implants and the stress in these implants increased in the apical direction with an increase in angle. Bellini et al 43 compared the produced stress of tilted implant designs in tilted and non-tilted ones in the maxillary bone. According to the results of this study, the tilted designs had less compressive stress compared to non-tilted models.

C. The length of the cantilever

In a study by Silva et al, 36 the produced stress pattern in implants in prostheses supported by 4 and 6 implants were compared. In this evaluation, the models were subjected to four loading conditions. The results indicated that in the presence of cantilever, Von Mises stress levels increased 100% in both models. In Bellini's study, 43 implant-supported prosthetic designs for mandible reconstruction using tilted and non-tilted implants were compared in terms of the stress levels. The first model included 4 implants, among which the distal implants were tilted and two different lengths of cantilever (5 mm and 15 mm) were used for each of the models. The third model consisted of 5 implants which were normally placed and the cantilever length in this case was 15 mm. The results showed that in the tilted model with the 5-mm cantilever and in non-tilted model, the maximum compressive stress level was observed adjacent to the neck of the distal implant. A greater level of compressive stress was inspected near the neck area of the distal implant in the tilted design model with a 15-mm cantilever.

Bevilacqua et al 40 evaluated the force transfer, using different angles of the implant and different cantilever lengths and the results showed that tilted implants that were splinted in complete fixed prostheses without cantilever caused a reduction in the stress levels in the bone around the implant compared to vertical implants and the cantilever segments.

In a study by Malhotra et al, 47 the force transfer was evaluated in tilted implants with different lengths of cantilever in All-On-Four position. In these models, the distal implants were tilted in different angles (30° and 40°) and different lengths of the cantilever (4 mm and 12 mm) were used. The results of this evaluation indicated that by increasing the angle in tilted distal implants, the stress levels do not increase significantly. In addition, there was no significant difference between the stress levels and the strain in 4- and 12-mm cantilevers in both positions of the distal implants (30° and 40°).

D. Stress level in the cortical and trabecular bone

Ozderuir et al 48 evaluated All-on-Four and alternative designs using FEA. Four models were assessed in this study:

First model: Implants were inserted according to All-on-Four design.

Second model: Two long implants (13 mm in length and 4 mm in diameter) and two short implants (7 mm in length and 4 mm in diameter).

Third model: 4 long implants and two short implants.

Fourth model: Two long implants and four short implants that were inserted vertically.

According to the results of this study, the stress concentration in the neck of the implant and in the cortical bone was significantly higher than the trabecular bone.


Conclusion

In terms of the implant number in some studies, it has been observed that by increasing the number of implants, a reduction will occur in the amount of stress in the bone and implant, while in others, the stress level did not change by increasing number of implants. In addition, regarding the different angles of implant placement, it seems that placing distal implants in an angular position results in better distribution of the force and stress. However, in some studies it has been mentioned that with increasing the angle, the stress on the peri-implant cortical bone would increase.

In terms of the cantilever length, it seems that using less cantilever lengths would reduce the stress.


Authors’ contributions

NKV designed the study and proposed preparation and acquisition of data. MRTA and AAA revised the work. MTB acquired data and revised the work. SS interpreted data and drafted the work and finally approved it


Competing interests

The authors declare no competing interest.


Ethics approval

There is no need for ethical approval for review articles.


References

  1. Babbush CA, Kutsko GT, Brokloff J. The all-on-four immediate function treatment concept with NobelActive implants: a retrospective study. Journal of Oral Implantology 2011; 37(4):431-445. [ Google Scholar]
  2. Association WM. World Medical Association Declaration of Helsinki Ethical principles for medical research involving human subjects. Bulletin of the World Health Organization 2001; 79(4):373. [ Google Scholar]
  3. Adell R, Eriksson B, Lekholm U, Brånemark P-I, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. International Journal of Oral & Maxillofacial Implants 1990; 5(4).
  4. Ortman HR. Factors of bone resorption of the residual ridge. The Journal of Prosthetic Dentistry 1962; 12(3):429-440. [ Google Scholar]
  5. Allen PF, McMillan AS. A review of the functional and psychosocial outcomes of edentulousness treated with complete replacement dentures. Journal (Canadian Dental Association) 2003; 69(10):662-662. [ Google Scholar]
  6. Attard NJ, Zarb GA. Long-term treatment outcomes in edentulous patients with implant overdentures: the Toronto study. The Journal of Prosthetic Dentistry 2005; 93(2):170. [ Google Scholar]
  7. Jivraj S, Chee W. Treatment planning of implants in posterior quadrants. British dental journal 2006; 201(1):13-23. [ Google Scholar]
  8. Carinci F, Farina A, Zanetti U. Alveolar ridge augmentation: a comparative longitudinal study between calvaria and iliac crest bone grafts. Journal of Oral Implantology 2005; 31(1):39-45. [ Google Scholar]
  9. Kaneko T, Masuda I, Horie N, Shimoyama T. New bone formation in nongrafted sinus lifting with space-maintaining management: A novel technique using a titanium bone fixation device. Journal of Oral and Maxillofacial Surgery 2012; 70(3):e217-e224. [ Google Scholar]
  10. Misch CM. Bone augmentation of the atrophic posterior mandible for dental implants using rhBMP-2 and titanium mesh: clinical technique and early results. International Journal of Periodontics & Restorative Dentistry 2011; 31(6).
  11. Patzelt S, Bahat O, Reynolds MA, Strub JR. The All‐on‐Four Treatment Concept: A Systematic Review. Clinical implant dentistry and related research 2014; 16(6):836-855. [ Google Scholar]
  12. Del Fabbro M, Testori T, Francetti L, Weinstein R. Systematic review of survival rates for implants placed in the grafted maxillary sinus. International Journal of Periodontics & Restorative Dentistry 2004; 24(6).
  13. Del Fabbro M, Bellini CM, Romeo D, Francetti L. Tilted implants for the rehabilitation of edentulous jaws: a systematic review. Clinical implant dentistry and related research 2012; 14(4):612-621. [ Google Scholar]
  14. Aparicio C, Perales P, Rangert B. Tilted implants as an alternative to maxillary sinus grafting: a clinical, radiologic, and periotest study. Clinical implant dentistry and related research 2001; 3(1):39-49. [ Google Scholar]
  15. Fortin Y, Sullivan RM, Rangert BR. The Marius Implant Bridge: Surgical and Prosthetic Rehabilitation for the Completely Edentulous Upper Jaw with Moderate to Severe Resorption: A 5‐Year Retrospective Clinical Study. Clinical implant dentistry and related research 2002; 4(2):69-77. [ Google Scholar]
  16. Krekmanov L, Kahn M, Rangert B, Lindström H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. International Journal of Oral & Maxillofacial Implants 2000; 15(3).
  17. Rossetti PHO, Bonachela WC, Rossetti LMN. Relevant anatomic and biomechanical studies for implant possibilities on the atrophic maxilla: critical appraisal and literature review. Journal of Prosthodontics 2010; 19(6):449-457. [ Google Scholar]
  18. Sun HL, Wu YR, Huang C, Shi B. Failure rates of short (≤ 10 mm) dental implants and factors influencing their failure: a systematic review. International Journal of Oral & Maxillofacial Implants 2011; 26(4).
  19. Meimandi M, Ardakani MRT, Amid R, Motlagh AM, Beheshti S. Comparison of Stress and Strain Distribution Around Splinted and Nonsplinted 6-mm Short Implants in Posterior Mandible: A Finite Element Analysis Study. Implant dentistry 2018; 27(1):74-80. [ Google Scholar]
  20. Maló P, Araújo Nobre M, Lopes A, Ferro A, Gravito I. All‐on‐4® Treatment Concept for the Rehabilitation of the Completely Edentulous Mandible: A 7‐Year Clinical and 5‐Year Radiographic Retrospective Case Series with Risk Assessment for Implant Failure and Marginal Bone Level. Clinical implant dentistry and related research 2015; 17(S2).
  21. Malo P, de Araújo Nobre M, Lopes A, Moss SM, Molina GJ. A longitudinal study of the survival of All-on-4 implants in the mandible with up to 10 years of follow-up. The Journal of the American Dental Association 2011; 142(3):310-320. [ Google Scholar]
  22. Maló P, Rangert B, Nobre M. “All‐on‐Four” Immediate‐Function Concept with Brånemark System® Implants for Completely Edentulous Mandibles: A Retrospective Clinical Study. Clinical implant dentistry and related research 2003; 5(s1):2-9. [ Google Scholar]
  23. Maló P, de Araújo Nobre M, Lopes A, Francischone C, Rigolizzo M. “All‐on‐4” Immediate‐Function Concept for Completely Edentulous Maxillae: A Clinical Report on the Medium (3 Years) and Long‐Term (5 Years) Outcomes. Clinical implant dentistry and related research 2012; 14(s1).
  24. Krekmanov L. Placement of posterior mandibular and maxillary implants in patients with severe bone deficiency: a clinical report of procedure. International Journal of Oral & Maxillofacial Implants 2000; 15(5).
  25. Watanabe F, Hata Y, Komatsu S, Ramos TC, Fukuda H. Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution. Odontology 2003; 91(1):31-36. [ Google Scholar]
  26. Testori T, Del Fabbro M, Capelli M, Zuffetti F, Francetti L, Weinstein RL. Immediate occlusal loading and tilted implants for the rehabilitation of the atrophic edentulous maxilla: 1‐year interim results of a multicenter prospective study. Clinical oral implants research 2008; 19(3):227-232. [ Google Scholar]
  27. Malo P, de Araujo Nobre M, Lopes A. The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months. The Journal of prosthetic dentistry 2007; 97(6):S26-S34. [ Google Scholar]
  28. Tealdo T, Bevilacqua M, Pera F. Immediate function with fixed implant-supported maxillary dentures: a 12-month pilot study. Journal of Prosthetic Dentistry 2008; 99(5):351-360. [ Google Scholar]
  29. Fischer K, Stenberg T. Early loading of ITI implants supporting a maxillary full-arch prosthesis: 1-year data of a prospective, randomized study. International Journal of Oral & Maxillofacial Implants 2004; 19(3).
  30. Jemt T. Fixed implant‐supported prostheses in the edentulous maxilla A five‐year follow‐up report. Clinical oral implants research 1994; 5(3):142-147. [ Google Scholar]
  31. Rocci A, Rocci M, Scoccia A, Martignoni M, Gottlow J, Sennerby L. Immediate loading of maxillary prostheses using flapless surgery, implant placement in predetermined positions, and prefabricated provisional restorations Part 2: a retrospective 10-year clinical study. International Journal of Oral & Maxillofacial Implants 2012; 27(5).
  32. Thiel CP, Evans DB, Burnett RR. Combination syndrome associated with a mandibular implant-supported overdenture: a clinical report. The Journal of prosthetic dentistry 1996; 75(2):107-113. [ Google Scholar]
  33. Weinstein AM, Klawitter JJ, Anand SC, Schuessler R. Stress analysis of porous rooted dental implants. Journal of Dental Research 1976; 55(5):772-777. [ Google Scholar]
  34. Gallagher RH. Finite element analysis: fundamentals. 1975.
  35. Geng J-P, Tan KB, Liu G-R. Application of finite element analysis in implant dentistry: a review of the literature. The Journal of prosthetic dentistry 2001; 85(6):585-598. [ Google Scholar]
  36. Silva GC, Mendonça JA, Lopes LR, Landre Jr J. Stress patterns on implants in prostheses supported by four or six implants: a three-dimensional finite element analysis. International Journal of Oral & Maxillofacial Implants 2010; 25(2).
  37. Fazi G, Tellini S, Vangi D, Branchi R. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. International Journal of Oral & Maxillofacial Implants 2011; 26(4).
  38. Takahashi T, Shimamura I, Sakurai K. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept. Journal of prosthodontic research 2010; 54(4):179-184. [ Google Scholar]
  39. Lan T-H, Huang H-L, Wu J-H, Lee H-E, Wang C-H. Stress analysis of different angulations of implant installation: the finite element method. The Kaohsiung journal of medical sciences 2008; 24(3):138-143. [ Google Scholar]
  40. Bevilacqua M, Tealdo T, Pera F. Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths. International Journal of Prosthodontics 2008; 21(6).
  41. Sasaki K, Matsushita Y, Tsukiyama Y, Esaki D, Koyano K. Stress analysis of all-on-4 system using a 3-dimensional finite element method. Prosthodontic research & practice 2008; 7(2):147-149. [ Google Scholar]
  42. Bellini CM, Romeo D, Galbusera F. Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study. International Journal of Oral & Maxillofacial Implants 2009; 24(3).
  43. Bellini CM, Romeo D, Galbusera F. A finite element analysis of tilted versus nontilted implant configurations in the edentulous maxilla. International Journal of Prosthodontics 2009; 22(2).
  44. Cruz M, Wassall T, Toledo EM, da Silva Barra LP, Cruz S. Finite element stress analysis of dental prostheses supported by straight and angled implants. International Journal of Oral & Maxillofacial Implants 2009; 24(3).
  45. Bevilacqua M, Tealdo T, Menini M. The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. The Journal of prosthetic dentistry 2011; 105(1):5-13. [ Google Scholar]
  46. Naini RB, Nokar S, Borghei H, Alikhasi M. Tilted or parallel implant placement in the completely edentulous mandible? A three-dimensional finite element analysis. International Journal of Oral & Maxillofacial Implants 2011; 26(4).
  47. Malhotra A, Padmanabhan T, Mohamed K, Natarajan S, Elavia U. Load transfer in tilted implants with varying cantilever lengths in an all‐on‐four situation. Australian dental journal 2012; 57(4):440-445. [ Google Scholar]
  48. Özdemir Doğan D, Polat NT, Polat S, Şeker E, Gül EB. Evaluation of “All‐on‐Four” Concept and Alternative Designs with 3D Finite Element Analysis Method. Clinical implant dentistry and related research 2014; 16(4):501-510. [ Google Scholar]
  49. Baggi L, Pastore S, Di Girolamo M, Vairo G. Implant-bone load transfer mechanisms in complete-arch prostheses supported by four implants: a three-dimensional finite element approach. The Journal of prosthetic dentistry 2013; 109(1):9-21. [ Google Scholar]
  50. Hussein MO, Rabie ME. Three-dimensional nonlinear contact finite element analysis of mandibular All-on-4 design. Journal of Oral Implantology 2015; 41(2):e12-e18. [ Google Scholar]
  51. Sannino G. All-on-four concept: a three-dimensional finite element analysis. J Oral Implantol 2013.
  52. Şeker E, Ulusoy M, Ozan O, Doğan DÖ, Şeker BK. Biomechanical effects of different fixed partial denture designs planned on bicortically anchored short, graft-supported long, or 45-degree-inclined long implants in the posterior maxilla: a three-dimensional finite element analysis. International Journal of Oral & Maxillofacial Implants 2014; 29(1).
Submitted: 19 Sep 2018
Revised: 30 Dec 2018
Accepted: 03 Jan 2019
First published online: 19 Jan 2019
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - FireFox Plugin)

Abstract View: 1009
PDF Download: 636
Full Text View: 97