Logo-japid
Submitted: 22 Jul 2017
Revision: 05 Feb 2018
Accepted: 30 May 2018
ePublished: 10 Oct 2018
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

J Adv Periodontol Implant Dent. 2018;10(1): 24-28.
doi: 10.15171/japid.2018.005
  Abstract View: 221
  PDF Download: 135

Research Article

Correlation of keratinized tissue width and periodontal indices around implant-supported fixed partial dentures

Ilnaz Farhoudi 1, Soheil Parsay 2*

1 Ardabil University of Medical Sciences, Ardabil, Iran
2 Private Practice, Ardabil, Iran
Corresponding Author; E-mail: Elnaz.farhoodi@gmail.com

Abstract

Background. The effect of keratinized tissue width on the peri-implant health has not been well elucidated. The results of previous studies on this topic are controversial and the role of keratinized tissue width in the long-term success of dental implants has not been confirmed. This cross-sectional study aimed to assess the correlation of keratinized tissue width with periodontal indices around implant-supported fixed partial dentures (FPDs). Methods. This cross-sectional study evaluated 73 implants. Patients underwent periodontal examinations, including measurement of plaque index (PI), gingival index (GI), clinical probing depth (PD), bleeding on probing (BOP), marginal gingival recession, keratinized mucosa width and radiographic marginal bone level. Data were analyzed using SPSS. Results. The mean GI, PI and marginal gingival recession around implants with <2 mm width of keratinized gingiva were greater than the corresponding values around implants with keratinized tissue width of ≥2 mm. However, this difference was not statistically significant (P>0.05). No significant differences were noted in PD and radiographic marginal bone level between the two implant groups with keratinized tissue width <2 mm and ≥2 mm. Thus, no correlation was found between the keratinized tissue width and the measured indices. Conclusion. Although this study did not show a significant correlation between the keratinized tissue width and peri-implant tissue health and consequently the implant success rate, long-term interventional studies are required to make a final judgment in this respect.
Keywords: Dental implants, keratinized tissue, peri-implant mucosa
First Name
 
Last Name
 
Email Address
 
Comments
 
Security code


Abstract View: 221

Your browser does not support the canvas element.


PDF Download: 135

Your browser does not support the canvas element.