Logo-japid
J Adv Periodontol Implant Dent. 2022;14(2): 62-68.
doi: 10.34172/japid.2022.015
PMID: 36714091
PMCID: PMC9871185
  Abstract View: 432
  PDF Download: 406
  Full Text View: 275

Research Article

Evaluation of the effect of autologous conditioned serum on the radiographic characteristics of hard tissue after horizontal bone augmentation in implant dentistry

Hamidreza Mohammadi 1 ORCID logo, Adileh Shirmohammadi 1* ORCID logo, Amirreza Babaloo 1, Leila Roshangar 2, Zeinab Torab 3, Mehdi Mojtahedinia 1

1 Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
2 Department of Histology and Embryology, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
3 Department of Pediatric Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: Corresponding author: Adileh Shirmohammadi, E-mail: , Email: shirmohamadia@yahoo.com

Abstract

Background. Bone deficiency in different areas is problematic in implant placement. Changes in histological, histomorphometric, and radiographic properties of hard tissues in the implant placement area affect many parameters of implant success. Autologous conditioned serum (ACS) is a blood product with high levels of IL1- receptor antagonists. Augmentation surgeries are required in many cases because implant placement in the edentulous areas requires a sufficient amount of bone. Therefore, this study radiographically evaluated the effect of autologous conditioned serum after horizontal bone augmentation.

Methods. In this prospective RCT, 21 patients eligible patients were evaluated. The patient underwent horizontal ridge augmentation surgery in the area. The ACS-impregnated graft was in direct con­tact with the bone. The control side underwent the same surgical protocol without using ACS. Four months after surgery, a CBCT radiograph was taken, and radiographic changes in the two areas were calculated using the differences in the amount of bone formed in the horizontal dimension as well as the Hounsfield unit (HU). The data were reported using descriptive statistical methods, including means (standard deviations) and frequencies (percentages). According to the results of the Kolmog­orov-Smirnov test, the data had a normal distribution (P>0.05); therefore, paired t-test was used to compare the means of the parameters between the two groups.

Results. IRadiographic examinations showed that the horizontal dimension of bone before surgery was similar between the two groups. However, after surgery in the ACS group (33.13±6.1), it was significantly higher than in the control group (62.1±86.4) (P>0.05). Also, the rate of horizontal dimension increase (the difference before and after surgery) in the ACS group was significantly higher than in the control group. Bone density before surgery was similar between the two groups. However, after surgery, there was a significant increase in the ACS group (75.56±330.42 HUs) compared to the control group (38.35±292.38 HUs) (P>0.05). Also, the rate of density increase (the difference before and after surgery) in the ACS group was significantly higher than in the control group.

Conclusion. Radiographic evaluations of hard tissues showed a significant increase in the horizontal dimension of bone and density of newly formed bone using ACS compared to the control group.

First Name
Last Name
Email Address
Comments
Security code


Abstract View: 419

Your browser does not support the canvas element.


PDF Download: 406

Your browser does not support the canvas element.


Full Text View: 275

Your browser does not support the canvas element.

Submitted: 24 Jul 2022
Revision: 10 Aug 2022
Accepted: 24 Aug 2022
ePublished: 26 Oct 2022
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)